SKU-A01

Product name

Detailed product description.

Product Description

Detailed product description.

Key features

Key feature 1

  • Details of the list of key features
  • Details of the list of key features
  • Details of the list of key features

Key feature 2

  • Details of the list of key features
  • Details of the list of key features
  • Details of the list of key features

Key feature 3

  • Details of the list of key features
  • Details of the list of key features
  • Details of the list of key features

Interested in this or other products? Contact us.

We will use the data to send you information. See Privacy Policy.

Technical Data

Technical DataQH-S3KQH-S3.6KQH-S4KQH-S5KQH-S6K
Input DC (PV side)
Maximum PV access power6kW7.2kW8kW10kW12kW
Maximum PV input power4.68kW5.76kW6.4kW8kW9.6kW
Maximum PV input voltage500V
Start-up voltage100V
MPPT voltage range150V~425V
Rated PV input voltage370V
Maximum operating PV input current20A / 20A
Maximum input short-circuit current30A / 30A
Number of MPPT / strings per MPPT2 / 1+1
Battery input data
Battery typeLithium / Lead-acid / Sodium
Battery voltage range40V~60V
Maximum charge/discharge current62.5A100A
CommunicationCAN
Number of battery input1
AC input/output data
Rated AC input/output active power3kW3.6kW4kW5kW6kW
Maximum AC input/output apparent power3.3kVA3.96kVA4.4kVA5.5kVA6.6kVA
Rated AC input/output current13.7A / 13.1A16.4A / 15.7A20.9A / 20A22.8A / 21.7A27.3A / 26.1A
Maximum AC input/output Current15.1A / 14.4A18A / 17.3A23A / 22A25.1A / 23.9A30A / 28.7A
Maximum continuous AC passthrough (grid to load)35A40A
Peak power (off-grid)2 times of rated power, 10s
Power factor adjustment range0.8 leading to 0.8 lagging
Rated input/output voltage/range220V/230V 0.85Un-1.1Un
Rated input/output grid frequency/range50Hz/45-55Hz, 60Hz/55-65Hz
Grid connection formL+N+PE
Total current harmonic distortion THDi<3% (of nominal power)
DC injection current<0.5% In
Efficiency
Maximum efficiency97,10%
Euro efficiency96,50%
MPPT efficiency>99%
Equipment protection
IntegratedDC reverse-polarity protection, Short circuit protection, Output over current protection, Surge protection (DC Type II / AC Type II), Ground fault monitoring, Integrated AFCI (DC arc-fault circuit protection, Activation required), Protection class/Over voltage category (I/II)
Surge protection levelType II (DC), Type II (AC)
Interface
Communication interfaceRS485/CAN
Monitor modeRS485, Wi-Fi, GPRS (optional)
General data
DC connectionMC4 connector
AC connectionQuick connection plug
Display69.6×55 mm LCD screen display
Operating temperature-40ºC~60ºC (derating above 45ºC)
Operating relative humidity0%~100%
Maximum operating altitude2000 m
Ingress protection ratingIP65
Inverter topologyNon-isolated
Over voltage categoryOVC II (DC), OVC III (AC)
Cooling methodNatural cooling
Weight20 kg
Dimensions (WxDxH)418x340x231 mm
Grid regulationCEI 0-21, UNE 217002
Safety / EMC StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Scroll to Top